Technical Documentation Guide

Technical Documentation for CE Marking: What You Need & How to Build It

Technical documentation is the evidence backbone of CE marking. Market surveillance authorities can request it at any time, and a Notified Body reviews it in detail. This guide explains what goes in the technical file, how to structure it, and the most common mistakes manufacturers make.

What Is Technical Documentation?

Technical documentation (also called a technical file) is the complete package of documents that demonstrates how your product meets the essential requirements — or general safety and performance requirements — of the applicable EU directive or regulation.

It is a legal requirement, not optional. The manufacturer must compile and maintain it before affixing the CE mark. For products requiring Notified Body assessment, the NB reviews the technical documentation as part of its conformity assessment. For self-declaration products, market surveillance authorities can request the technical file at any time.

The technical documentation must remain available for 10 years after the last product is placed on the market (15 years for implantable medical devices under MDR).

Technical Documentation Under MDR (Annexes II and III)

MDR 2017/745 defines the most detailed and prescriptive technical documentation requirements of any EU product regulation. Annex II covers the main technical documentation; Annex III covers post-market surveillance technical documentation.

MDR Annex II — Technical Documentation (Main File)

  • Device description and specification, including variants and accessories
  • Reference to previous and similar generations of the device
  • Information to be supplied by the manufacturer (labelling, IFU)
  • Design and manufacturing information (materials, components, manufacturing process, sterilisation)
  • General Safety and Performance Requirements (GSPR) checklist with compliance justification
  • Benefit-risk analysis and risk management (per ISO 14971)
  • Product verification and validation (test reports, biocompatibility, software validation, usability/human factors)
  • Clinical evaluation report (CER) — per MDR Annex XIV
  • Post-market clinical follow-up (PMCF) plan

MDR Annex III — Post-Market Surveillance Technical Documentation

  • Post-market surveillance (PMS) plan
  • Periodic Safety Update Report (PSUR) — for Class IIa, IIb, III
  • Summary of Safety and Clinical Performance (SSCP) — for Class III and implantable devices
  • Post-market clinical follow-up (PMCF) evaluation report

Technical Documentation for Non-Medical CE Products

For products outside MDR/IVDR — such as machinery, electronics, PPE, or construction products — the technical documentation requirements follow the applicable directive. While less prescriptive than MDR, they cover the same core elements:

Typical technical file structure (non-medical products)

  • General description of the product and its intended use
  • Overview design drawings and manufacturing process description
  • List of harmonised standards applied (fully or partially)
  • Description of solutions adopted to meet essential requirements where harmonised standards are not applied
  • Design calculations, technical specifications, and test results
  • Risk assessment (e.g. ISO 31000, EN ISO 12100 for machinery)
  • Test reports from accredited laboratories (for applicable standards)
  • Instructions for use and safety information
  • EU Declaration of Conformity

The GSPR Checklist for Medical Devices

One of the most important documents in an MDR technical file is the General Safety and Performance Requirements (GSPR) checklist. This document maps each requirement from MDR Annex I against your product and documents how compliance is demonstrated — typically through reference to harmonised standards, test reports, risk management outputs, or other evidence.

A well-structured GSPR checklist:

Risk Management — The Core of Any Technical File

Risk management documentation is central to technical files across all product categories. For medical devices, ISO 14971 is the internationally harmonised standard for medical device risk management. For machinery, EN ISO 12100 covers risk assessment and risk reduction.

A complete risk management file includes:

Clinical Evaluation for Medical Devices (MDR)

Under MDR, the Clinical Evaluation Report (CER) is one of the most demanding elements of the technical documentation. It must demonstrate that the device achieves its intended purpose and that the benefit-risk balance is acceptable based on clinical data — not just preclinical testing.

Clinical data sources for the CER include:

⚠ Equivalence claims under MDR are strictly controlled MDR has significantly tightened the conditions for claiming equivalence to another device for clinical data purposes. For Class III and implantable devices, a contract giving access to the equivalent device's technical documentation is required. Many equivalence claims accepted under MDD are no longer valid under MDR.

Common Technical Documentation Mistakes

Maintaining Technical Documentation After CE Marking

CE marking is not a one-time event. Technical documentation must be maintained and updated throughout the product's lifecycle:

Frequently Asked Questions

How long must I keep technical documentation for CE marking?
At least 10 years after the last product is placed on the market. For implantable medical devices under MDR, 15 years. The documentation must be available to market surveillance authorities on request throughout this period.
Does technical documentation need to be in a specific language?
Technical documentation itself has no specific language requirement — it's for regulatory authorities and Notified Bodies. However, the Declaration of Conformity, IFU, and labels must be in the official language(s) of the member states where the product is sold.
Can I use existing test data (e.g. from FDA submission) for CE marking?
Sometimes. Existing data may be usable if it covers the same product and test methods meet applicable EU harmonised standards. A regulatory consultant can assess what existing data is leverageable and what additional EU-specific testing is needed.
What is the difference between a technical file and technical documentation?
These terms are interchangeable. 'Technical file' is the older term used in pre-MDR directives. MDR uses 'technical documentation' and specifies content in Annexes II and III. Both refer to the same complete evidence package.

Ready to Start?

Complete guide to technical documentation for CE marking: what must be included, structure for medical devices vs.

Search Testing Labs Free →